Short Circuits(단락)란 무엇입니까?
Short Circuits 단락 - Furthermore, the problem of short circuits that results due to crossing is discussed because of the proposed study where an algorithm based on complex QROF (CQROF) information is presented for reducing the crossing in networks. [1] This paper demonstrates the concept of probabilistic stability assessment on large-signal stability in the use case of short circuits in an active distribution grid. [2] This article shows how thermographic devices can facilitate the early detection of faults in the electricity distribution network before they can cause the interruption of operation and cause damages and incidents due to short circuits and fires. [3] Due to the severity of short circuits or current leaks in Li-ion batteries, the proposed method uses a residual threshold to identify faults in the fast-acting voltage signal. [4] However, uncontrollable dendrite growth during the repeated Na plating/stripping process leads to the issues of low Coulombic efficiency and short circuits, impeding the practical applications of Na metal anodes. [5] This reduces both short circuits and recirculation zones bringing the flow closer to the ideal plug-flow condition. [6] As a result, whenever the servo feed becomes faster than the material removal rate, short circuits and wire break occur. [7] Due to its chemical inertness, the adhesion between two polyimide layers is, however, a challenge, which can lead to delamination and, finally, to short circuits. [8] The results obtained show that in standard circuits of PSS for linear consumers with short circuits in the supply network, voltage dips occur, the depth of which reaches 100%. [9] Short circuits and open circuits are commonly considered as the two main types of faults. [10] These generator sets generate a lot of harmful gases and CO2 and in-cases of over loading lead to short circuits and also fire. [11] Severe building damage and consequently broken pipelines can lead to release of flammable gasses and liquid, which increase possibility of fire occurrence when they come into contact with ignition sources, like short circuits or open flames. [12] The generator with Alnico 8 permanent magnets have the highest output power, is good at handling the nominal load but the most sensitive to short circuits. [13] The designed system is resilient under the events like grid outage and short circuits. [14] The current condensation phenomenon inside the ring main unit will cause corrosion of components, short circuits, partial discharges and other problems, which will seriously affect the safety and durability of power supply. [15] Short circuits are a matter of major concern in the protection of power distribution systems. [16] Protection against short circuits in microgrid networks with distributed generation is proposed, in which the power of the power sources and loads are constantly changing, which leads to a change in the sensitivity of relay protection. [17] Otherwise, a too small position distance may cause safety problems, such as short circuits and thermal runaway. [18] Herein, we demonstrate that by using an anion-exchange membrane, quaternary ammonia poly (N-methyl-piperidine-co-p-terphenyl) (QAPPT), as the separator, the damage from short circuits can be completely prevented. [19] Hard faults indicate open/short circuits that can lead to serious breakdowns because they prevent the flow of energy or information. [20] The aging of the insulating system is influenced by several factors including high loading profile, temperature rise, and short circuits. [21] But severe safety issues such as cracks or breakage, resulting in short circuits will prevent their widespread application. [22] The multilayered PLA garment superseded the single-layered garment with higher levels of accuracy in the yielded results due to the enhanced design layout, which reduces the potential for short circuits and errors occurring. [23] One of the most essential consequences of short circuits in underground cable networks of 6–10 kV is heating up the insulation with its possible inflammation and damage of adjacent objects of an electrical supply system that enlarge the concomitant damage many times as much. [24] Achieving a good surface finish with higher material removal is difficult in Micro ED (μED) Milling due to the short circuits and arcing attributed to partial removal of debris. [25] This research work focuses on the safe operation of an electric power system from external and internal impulses arising due to lightning strikes or short circuits. [26] Several types of faults are considered, such as short circuits and line and load contingencies. [27] In WEDM, whenever the wire is fed too fast, the process will be interrupted not only by short circuits, but the wire electrode is most likely to break, jeopardising process efficiency in many ways. [28] The separator was used to secure the battery by preventing it from short circuits. [29] Differences in the processes in the core legs and yokes when transformer is connected to the network and during short circuits of the windings are noted. [30] To obtain a comprehensive classification, different connections of transformer windings as well as various types of short circuits are considered, and the influence of these classes on the Induction Motor (IM) performance is rendered. [31] To create data, we use a wind turbine simulator that enables fully coupled nonlinear time-domain numerical simulations of offshore wind turbines considering six fault types including biases and fixed outputs in pitch sensors and excessive friction, slit lock, incorrect voltage, and short circuits in actuators. [32] , overheating, overloading and short circuits). [33] An anode prepared using Li-infused oxidised Ni-foam showed no evidence of short circuits or dendrite formation after 1000 cycles of stripping and plating at 0. [34] The possible current short circuits by droplet or continuous thin film pathways through the condensate layer were modelled using finite element techniques and confirmed to be insignificant even for a fluid with an electrical conductivity equivalent to that of seawater, more than two orders of magnitude above that of the condensed fluid. [35] Specifically, difficulties arise in measuring materials with high imaginary permittivity or low impedance, which act as short circuits, either exceeding the measurement equipment damage threshold or that of the material under test, and/or inducing an unacceptable signalto-noise in the collected data. [36] Introduction: Fire cases increase in residential buildings because short circuits, at dormitories are mostly affected by human factors. [37] In this context, short circuits of production and food supply have become widely demanded alternatives, as feasible, viable and productive solutions in short-term results. [38] 534 μm due to increased discharge energy, the improved flushing of the IG and the reduced occurrence of local high-temperature breakdowns—evidenced by a decrease in the depth and number of deep craters formed due to current localization during short circuits—significantly reduced contamination of the surface layer and the crater formation rate. [39] Then, this paper studies the influence of the ratio of positive and negative pulses on short circuits, the influence of the ratio of positive and negative pulses on the mass removal rate, and the influence of the electrolyte concentration and pulse width on the mass removal rate. [40] This article extends previous work by using a common electrical load in place of previously used capacitors, inductors, and short circuits. [41] Protection against short circuits between buses tubes in short networks of ore-thermal furnaces is provided by means of electrical insulation. [42] After several times repeated cold straightening, the cathode blank spring backs to its distorted position during electrorefining resulted in short circuits and current efficiency decreases. [43] Defects introduced in the production of electrodes can lead to degraded performance and, more importantly, to short circuits in final cells, which is highly safety-critical. [44]또한 네트워크에서 교차를 줄이기 위해 복잡한 QROF(CQROF) 정보에 기반한 알고리즘이 제시되는 제안된 연구 때문에 교차로 인해 발생하는 단락 문제가 논의됩니다. [1] 이 논문은 능동 배전 계통에서 단락 회로의 사용 사례에서 대신호 안정성에 대한 확률적 안정성 평가의 개념을 보여줍니다. [2] 이 기사에서는 열화상 장치가 작동 중단을 일으키고 단락 및 화재로 인한 손상 및 사고를 일으키기 전에 배전 네트워크의 결함을 조기에 감지할 수 있는 방법을 보여줍니다. [3] 리튬 이온 배터리의 단락 또는 전류 누출의 심각성으로 인해 제안된 방법은 잔류 임계값을 사용하여 빠르게 작동하는 전압 신호의 오류를 식별합니다. [4] 그러나 반복되는 Na 도금/스트리핑 공정 동안 제어할 수 없는 덴드라이트 성장은 낮은 쿨롱 효율 및 단락 문제를 유발하여 Na 금속 양극의 실제 적용을 방해합니다. [5] 이는 단락 및 재순환 영역을 모두 줄여 흐름을 이상적인 플러그 흐름 조건에 더 가깝게 만듭니다. [6] 그 결과, 서보 피드가 재료 제거 속도보다 빨라질 때마다 단락 및 단선이 발생합니다. [7] 그러나 화학적 불활성으로 인해 두 폴리이미드 층 사이의 접착은 문제가 되며, 이는 박리 및 최종적으로 단락으로 이어질 수 있습니다. [8] 얻은 결과는 공급 네트워크에 단락이 있는 선형 소비자를 위한 PSS의 표준 회로에서 전압 강하가 발생하고 그 깊이는 100%에 도달함을 보여줍니다. [9] 단락 및 개방 회로는 일반적으로 두 가지 주요 유형의 결함으로 간주됩니다. [10] 이러한 발전기 세트는 많은 유해 가스와 CO2를 생성하며 과부하 시 합선 및 화재로 이어집니다. [11] 심각한 건물 손상 및 결과적으로 파손된 파이프라인은 가연성 가스 및 액체의 방출로 이어질 수 있으며, 이는 합선이나 화염과 같은 점화원과 접촉할 때 화재 발생 가능성을 높입니다. [12] Alnico 8 영구자석이 있는 발전기는 출력이 가장 높고 공칭 부하를 잘 처리하지만 단락에 가장 민감합니다. [13] 설계된 시스템은 계통 정전 및 단락과 같은 이벤트에서 탄력적입니다. [14] 링 본체 내부의 전류 응축 현상은 구성 요소의 부식, 단락, 부분 방전 및 기타 문제를 일으켜 전원 공급 장치의 안전성과 내구성에 심각한 영향을 미칩니다. [15] 단락은 배전 시스템 보호에서 주요 관심사입니다. [16] 전원 및 부하의 전력이 지속적으로 변경되어 계전기 보호 감도가 변경되는 분산 발전이 있는 마이크로 그리드 네트워크의 단락에 대한 보호가 제안됩니다. [17] 그렇지 않으면 너무 작은 위치 거리로 인해 단락 및 열 폭주와 같은 안전 문제가 발생할 수 있습니다. [18] 여기서 우리는 음이온 교환막인 4차 암모니아 폴리(N-메틸-피페리딘-co-p-터페닐)(QAPPT)를 분리막으로 사용하여 단락으로 인한 손상을 완전히 방지할 수 있음을 보여줍니다. [19] 하드 오류는 에너지 또는 정보의 흐름을 방해하기 때문에 심각한 고장으로 이어질 수 있는 개방/단락을 나타냅니다. [20] 절연 시스템의 노후화는 높은 부하 프로파일, 온도 상승 및 단락을 포함한 여러 요인의 영향을 받습니다. [21] 그러나 균열이나 파손과 같은 심각한 안전 문제로 인해 단락이 발생하면 광범위한 적용이 불가능합니다. [22] 다중 레이어 PLA 의류는 향상된 디자인 레이아웃으로 인해 산출 결과에서 더 높은 수준의 정확도로 단일 레이어 의류를 대체하여 단락 및 오류 발생 가능성을 줄입니다. [23] 6–10kV의 지하 케이블 네트워크에서 단락의 가장 중요한 결과 중 하나는 수반되는 손상을 몇 배나 확대하는 전기 공급 시스템의 인접 물체의 손상 및 염증 가능성으로 절연체를 가열하는 것입니다. [24] Micro ED(μED) 밀링에서 더 높은 재료 제거로 우수한 표면 조도를 달성하는 것은 파편의 부분적 제거로 인한 단락 및 아크로 인해 어렵습니다. [25] 본 연구는 낙뢰 또는 합선으로 인해 발생하는 외부 및 내부 충격으로부터 전력 시스템의 안전한 작동에 중점을 둡니다. [26] 단락, 라인 및 부하 우발 상황과 같은 여러 유형의 오류가 고려됩니다. [27] WEDM에서는 와이어가 너무 빨리 공급될 때마다 단락으로 인해 프로세스가 중단될 뿐만 아니라 와이어 전극이 파손될 가능성이 가장 높아 여러 면에서 프로세스 효율성을 위태롭게 합니다. [28] 분리막은 배터리를 단락으로부터 보호하여 배터리를 고정하는 데 사용되었습니다. [29] 변압기가 네트워크에 연결될 때와 권선이 단락되는 동안 코어 레그와 요크의 프로세스 차이가 표시됩니다. [30] 포괄적인 분류를 얻기 위해 변압기 권선의 다양한 연결과 다양한 유형의 단락을 고려하고 이러한 등급이 IM(인덕션 모터) 성능에 미치는 영향을 렌더링합니다. [31] 데이터를 생성하기 위해 우리는 피치 센서의 바이어스 및 고정 출력과 과도한 마찰, 슬릿 잠금, 잘못된 전압 및 단락을 포함한 6가지 결함 유형을 고려하여 해상 풍력 터빈의 완전 결합된 비선형 시간 영역 수치 시뮬레이션을 가능하게 하는 풍력 터빈 시뮬레이터를 사용합니다. 액추에이터. [32] , 과열, 과부하 및 단락). [33] Li 주입 산화 Ni-foam을 사용하여 제조된 양극은 0에서 스트리핑 및 도금을 1000회 반복한 후 단락 또는 덴드라이트 형성의 증거를 나타내지 않았습니다. [34] 응축수층을 통과하는 액적 또는 연속적인 박막 경로에 의한 전류 단락은 유한 요소 기법을 사용하여 모델링되었으며 해수와 동일한 전기 전도도를 갖는 유체에 대해서도 응축된 유체. [35] 특히, 측정 장비 손상 임계값 또는 테스트 대상 재료의 임계값을 초과하거나 수집된 데이터에서 허용할 수 없는 신호 대 잡음을 유도하는 단락으로 작용하는 높은 가상 유전율 또는 낮은 임피던스를 갖는 재료를 측정하는 데 어려움이 발생합니다. [36] 소개: 주거용 건물의 화재 사례는 주로 인적 요인의 영향을 받는 기숙사의 합선으로 인해 증가합니다. [37] 이러한 맥락에서 생산 및 식품 공급의 단락은 단기 결과에서 실현 가능하고 실행 가능하며 생산적인 솔루션으로서 널리 요구되는 대안이 되었습니다. [38] 방전 에너지 증가, IG의 플러싱 개선 및 국부 고온 파괴 발생 감소로 인한 534μm(단락 시 전류 국부화로 인해 형성된 깊은 분화구 수 및 깊이 감소로 입증됨) 표면층과 분화구 형성 속도. [39] 그런 다음, 이 논문은 양의 펄스와 음의 펄스 비율이 단락 회로에 미치는 영향, 양과 음의 펄스 비율이 질량 제거율에 미치는 영향, 전해질 농도와 펄스 폭이 질량 제거율에 미치는 영향을 연구합니다. . [40] 이 기사에서는 이전에 사용된 커패시터, 인덕터 및 단락 회로 대신 공통 전기 부하를 사용하여 이전 작업을 확장합니다. [41] 광열로의 짧은 네트워크에서 버스 튜브 사이의 단락에 대한 보호는 전기 절연을 통해 제공됩니다. [42] 냉간 교정을 여러 번 반복한 후 음극 블랭크 스프링은 전기 정련 중에 왜곡된 위치로 되돌아가 단락을 발생시키고 전류 효율을 감소시킵니다. [43] 전극 생산에 도입된 결함은 성능 저하로 이어질 수 있으며 더 중요하게는 안전이 매우 중요한 최종 셀의 단락을 유발할 수 있습니다. [44]
human errors overload 인적 오류 과부하
TL are susceptible to faults in case of lightning, short circuits, mis-operation, human errors, overload, etc. [1] The problem with these lines are, because the loads are unbalanced and their attraction towards various faults as a results of lightning, short circuits, faulty equipment’s, miss-operation, human errors, overload, and aging. [2] These grid lines are exposed to faults as a result of lightning, short circuits, faulty equipment, mis-operation, human errors, overload, and aging among others. [3]TL은 낙뢰, 단락, 오작동, 인적 오류, 과부하 등의 경우 오류에 취약합니다. [1] 이러한 라인의 문제는 부하가 불균형하고 낙뢰, 단락, 장비 결함, 오작동, 인적 오류, 과부하 및 노후화의 결과로 다양한 결함에 끌리기 때문입니다. [2] nan [3]
high energy density 높은 에너지 밀도
Lithium dendrite (filament) propagation through ceramic electrolytes, leading to short circuits at high rates of charge, is one of the greatest barriers to realizing high-energy-density all-solid-state lithium-anode batteries. [1] Ni-rich high-energy-density lithium ion batteries pose great risks to safety due to internal short circuits and overcharging; they also have poor performance because of cation mixing and disordering problems. [2] Summary Lithium (Li)-metal is considered as promising anode material for high-energy-density rechargeable batteries, although its application is hampered by inhomogeneous Li deposition and dendritic Li morphologies that could eventually result in contact losses of bulk and deposited Li as well as cell short circuits. [3]세라믹 전해질을 통한 리튬 덴드라이트(필라멘트) 전파는 높은 충전율에서 단락을 유발하며, 이는 고에너지 밀도 전고체 리튬 양극 배터리를 구현하는 데 있어 가장 큰 장벽 중 하나입니다. [1] Ni이 풍부한 고에너지 밀도 리튬 이온 배터리는 내부 단락 및 과충전으로 인해 안전에 큰 위험을 초래합니다. 또한 양이온 혼합 및 무질서한 문제로 인해 성능이 좋지 않습니다. [2] 요약 리튬(Li)-금속은 불균일한 Li 증착과 수지상 Li 형태로 인해 응용이 방해를 받고 있지만 궁극적으로 벌크 및 증착된 Li 및 셀 단락. [3]
multi terminal offshore 멀티 터미널 오프쇼어
To improve the ride-through capability (RTC) of the multi-terminal offshore wind power flexible DC system in response to faults, this paper is based on the basic structure and control strategy of the voltage source converter (VSC) station of the multi-terminal offshore wind power flexible DC transmission system (MTDC), and aims at the AC grid connected to the system with three-phase short circuits and wind turbine output changes According to the situation, the mechanism of voltage drop caused by the fault is analyzed, and the DC chopper energy bleeder circuit is connected to the DC side to cooperate with the comprehensive control scheme for fault ride-through of multi-terminal offshore wind power flexible DC collection system. [1]본 논문은 다중단자 해상풍력 플렉시블 DC 계통의 고장대응 RTC(Ride-Through Capability)를 향상시키기 위해 다중단말기의 VSC(Voltage Source Converter) 스테이션의 기본 구조와 제어전략을 기반으로 한다. 터미널 해상풍력 플렉시블 DC 송전 시스템(MTDC), 3상 단락 및 풍력 터빈 출력 변화로 계통에 연결된 AC 계통을 목표로 상황에 따라 고장으로 인한 전압 강하 메커니즘을 분석하고, DC 초퍼 에너지 블리더 회로는 DC 측에 연결되어 다중 터미널 해상 풍력 가요성 DC 수집 시스템의 장애 통과를 위한 포괄적인 제어 체계와 협력합니다. [1]
Turn Short Circuits 턴 단락
Experimental results verify the proposed method, and inter-turn short circuits of two and three turns are confidently detected and located for a 500 W, two-pole IM. [1] Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). [2] In the absence of suitable thermal management systems, the electric machine losses can lead to insulation failure, inter-turn short circuits, de-magnetization of the permanent magnets, and finally drive system failure. [3] The paper presents a new practical and more precise model for induction motors after introducing inter turn short circuits faults. [4] The study shows the possibility of using an external magnetic field to detect inter-turn short circuits of the stator winding. [5] The most common reason for the failure of consumer transformers (over 50%) is turn-to-turn short circuits in their windings. [6] This paper proposes a comprehensive analysis of inter-turn short circuits (ISC) in interior permanent magnet synchronous machines (IPMSM). [7] Experimental results verify the proposed method, and inter-turn short circuits of two and three turns are confidently detected and located for a 500 W, two-pole IM. [8] This work proposes an alternative strategy to the use of a speed sensor in the implementation of active and reactive power based model reference adaptive system (PQ-MRAS) estimator in order to calculate the rotor and stator resistances of an induction motor (IM) and the use of these parameters for the detection of inter-turn short circuits (ITSC) faults in the stator of this motor. [9] Using a new approach to modeling processes occurring in an asynchronous motor during the inter-turn short circuit in one phase of the stator, pulsations of the torque on the motor shaft were studied for different values of the AC impedance and resistance of one of the stator winding phases, which corresponds to varying degrees of the inter-turn short circuits. [10] Stator winding faults are mainly inter-turn short circuits and are among the most common faults in electric motors. [11] Finally, the fault simulation analyses of winding inter-turn short circuits are performed based on the proposed equivalent electrical circuit. [12] This was done for the motor working under inter turn short circuits (three, six and nine turns short), unbalanced voltage fault or without fault conditions at different loads. [13] Despite the wide variety of methods, the reliability of determining the inter-turn short circuits of stator windings under operating voltage still remains at a low level. [14] Most studies have focused on diagnosing winding and core deformations, but subtle defects in the winding insulation and turn-to-turn short circuits can develop into a more serious fault, and their early diagnosis is equally important. [15] Turn-to-turn short circuits occur due to insulation damage in transformer windings and these may potentially result in catastrophic faults affecting electric networks. [16]실험 결과는 제안된 방법을 검증하고 500W, 2극 IM에 대해 2회 및 3회 턴의 턴 간 단락을 확실하게 감지하고 위치를 찾습니다. [1] 변압기 권선 내의 턴 간 단락은 임펄스 전압 기반 주파수 응답 분석(IFRA)을 통해 진단할 수 있습니다. [2] nan [3] 이 논문은 턴간 단락 오류를 도입한 후 유도 전동기에 대한 새롭고 실용적이고 정확한 모델을 제시합니다. [4] nan [5] nan [6] nan [7] nan [8] nan [9] nan [10] nan [11] nan [12] nan [13] nan [14] nan [15] nan [16]
Phase Short Circuits 위상 단락
A method and principles are discussed for universal multifrequency protection from single-phase short circuits to ground in compensated and uncompensated 6 – 10 kV cable networks based on monitoring the magnitude and sign of the zero-sequence capacitance using the components at the fundamental frequency and higher harmonics of the current and derivative of the zero sequence voltage. [1] The database includes information from voltage signals measured at each bar of the system and was assembled from simulations of three-phase, two-phase, and single-phase short circuits. [2] A series of experiments was carried out: two-phase and three-phase short circuits in various nodes of the scheme with and without the compensator and in various connection nodes. [3] To protect high-voltage electric motors (EM) from phase-to-phase short circuits, current cut-offs are widely used. [4] Single-phase and three-phase short circuits are simulated in DIgSILENT software on the IEEE 39 bus test system, using international standard IEC 60909. [5] The lines with a voltage of 500–1150 kV, the overwhelming proportion of blackouts is caused by single-phase short circuits, much of which, being unstable arc accidents are conveniently eliminated in a single-phase auto-reclosing cycle. [6] By considering different grounding methods of distribution bus side and DG side, distribution characteristics and change laws of fault current as well as sequence currents on both sides of fault point when single-phase short circuits occur in different positions of system are discussed. [7] To improve the ride-through capability (RTC) of the multi-terminal offshore wind power flexible DC system in response to faults, this paper is based on the basic structure and control strategy of the voltage source converter (VSC) station of the multi-terminal offshore wind power flexible DC transmission system (MTDC), and aims at the AC grid connected to the system with three-phase short circuits and wind turbine output changes According to the situation, the mechanism of voltage drop caused by the fault is analyzed, and the DC chopper energy bleeder circuit is connected to the DC side to cooperate with the comprehensive control scheme for fault ride-through of multi-terminal offshore wind power flexible DC collection system. [8] Simulation of single-phase short circuits with different active resistance in the short circuit place is carried out. [9] This, in turn, leads to the destruction of the insulation of the neutral and phase conductors and corresponding single-phase short circuits. [10] The insulation degradation of a voltage transformer winding is not easy to find, but it may ultimately cause the transformer to explode, leading to accidents such as phase-to-phase short circuits. [11]기본 주파수 이상에서 구성 요소를 사용하여 제로 시퀀스 커패시턴스의 크기와 부호를 모니터링하는 것을 기반으로 하는 보상 및 비보상 6 – 10kV 케이블 네트워크에서 단상 단락에서 접지까지의 범용 다중 주파수 보호를 위한 방법 및 원리에 대해 설명합니다. 전류의 고조파 및 제로 시퀀스 전압의 미분. [1] 데이터베이스에는 시스템의 각 막대에서 측정된 전압 신호의 정보가 포함되어 있으며 3상, 2상 및 단상 단락 회로의 시뮬레이션에서 조립되었습니다. [2] nan [3] nan [4] nan [5] nan [6] nan [7] 본 논문은 다중단자 해상풍력 플렉시블 DC 계통의 고장대응 RTC(Ride-Through Capability)를 향상시키기 위해 다중단말기의 VSC(Voltage Source Converter) 스테이션의 기본 구조와 제어전략을 기반으로 한다. 터미널 해상풍력 플렉시블 DC 송전 시스템(MTDC), 3상 단락 및 풍력 터빈 출력 변화로 계통에 연결된 AC 계통을 목표로 상황에 따라 고장으로 인한 전압 강하 메커니즘을 분석하고, DC 초퍼 에너지 블리더 회로는 DC 측에 연결되어 다중 터미널 해상 풍력 가요성 DC 수집 시스템의 장애 통과를 위한 포괄적인 제어 체계와 협력합니다. [8] nan [9] nan [10] nan [11]
Internal Short Circuits 내부 단락
Despite the huge expansion of electric vehicle sales in the market, customers are discouraged by the possible catastrophic consequences brought by the safety issues of lithium-ion batteries, such as internal short circuits, especially in crash scenarios. [1] In order to prevent internal short circuits and thermal runaways within a Li-ion battery, the separator plays a crucial role. [2] However, most LiBs assemble with organic solvent-based liquid electrolytes possessing the drawback of volatile, flammable and low decomposition temperature, so it suffers from toxicity, flammability, potential leakage, even explosion accidents when the LiBs are exposed to harsh conditions such as internal short circuits, high temperature and cell crush. [3] Degradation during operation of a battery can contribute to capacity fade, increased internal resistance, power fade, and internal short circuits, which lead to the loss of or decrease in propulsive power. [4] However, the inevitable safety issues always caused by poor mechanical integrity and internal short circuits of the thin separator must be addressed before this type of separator can be applied to lithium-ion batteries. [5] The most severe type of damage of the most common elements of electrical networks - high-voltage switchgears (switchgear) with a voltage of 6-10 kV are internal short circuits (SC), accompanied by an electric arc. [6] Internal short circuits and thermal runaway in lithium-ion batteries (LIBs) are mainly caused by deformation-induced failures in their internal components. [7] Summary Isolating electronically conducting material from internal short circuits is a promising way to prevent the onset of thermal runaway within lithium-ion cells. [8] Ni-rich high-energy-density lithium ion batteries pose great risks to safety due to internal short circuits and overcharging; they also have poor performance because of cation mixing and disordering problems. [9] These transformers are subject to internal short circuits, external short circuits and abnormal operating conditions. [10]시장에서 전기 자동차 판매가 크게 확대되고 있음에도 불구하고 고객은 특히 충돌 시나리오에서 내부 단락과 같은 리튬 이온 배터리의 안전 문제로 인해 발생할 수 있는 치명적인 결과에 대해 낙담하고 있습니다. [1] 리튬 이온 배터리 내부의 내부 단락 및 열 폭주를 방지하기 위해 분리막이 중요한 역할을 합니다. [2] nan [3] nan [4] nan [5] nan [6] nan [7] nan [8] Ni이 풍부한 고에너지 밀도 리튬 이온 배터리는 내부 단락 및 과충전으로 인해 안전에 큰 위험을 초래합니다. 또한 양이온 혼합 및 무질서한 문제로 인해 성능이 좋지 않습니다. [9] nan [10]
Cause Short Circuits 단락 원인
Optimum gap between conducting lines was found to be 300 µm with smaller gaps creating stray ink blotches that cause short circuits. [1] The existing electrode materials still have many problems: the shuttle effect and poor conductivity of the sulfur cathode, the inevitable volume expansion of the silicon anode and the lithium dendrite of the lithium metal anode that cause short circuits, etc. [2] It is eagerly required to prevent external stress type Sn whisker generated from Sn plating film on connecter joints because it causes short circuits. [3] Therefore, hanging foreign objects such as kites, balloons and plastic films can easily cause short circuits, and lead to shutdown accidents. [4] The main problem is that during cycling, Li can infiltrate along grain boundaries and cause short circuits, resulting in potentially catastrophic battery failure. [5] Water is detrimental to electronic devices because it easily causes short circuits. [6] When applied to Mg-Sb liquid metal batteries, we find that the electrovortex flows may have the capacity to cause short circuits even in moderate size batteries with radii in the range [10, 20] cm. [7]전도선 사이의 최적의 간격은 300μm로, 간격이 작을수록 단락을 유발하는 잉크 얼룩이 생기는 것으로 나타났습니다. [1] 기존의 전극 재료는 여전히 많은 문제를 가지고 있습니다. 황음극의 셔틀 효과 및 열악한 전도도, 단락을 유발하는 실리콘 양극 및 리튬 금속 음극의 리튬 덴드라이트의 불가피한 부피 팽창 등입니다. [2] nan [3] nan [4] nan [5] nan [6] nan [7]
Avoid Short Circuits 단락 방지
To overcome these obstacles, dexamethasone has recently been embedded in this type of implants: into the silicone matrices separating the metal electrodes (to avoid short circuits). [1] Nearby wells should be shut in during infill drilling operations to avoid short circuits, drilling mud losses, completions damage, and well integrity failures. [2] Magnetostrictive elements (Ni and CoFeB) were deposited in the proximity of the interdigitated transducers (IDTs) of the resonators (A-type structures) and also over the IDTs, after covering them with a BCB layer to avoid short circuits with IDTs metal (B-type structures). [3]이러한 장애물을 극복하기 위해 덱사메타손은 최근 이러한 유형의 임플란트에 삽입되었습니다. 즉, 단락을 방지하기 위해 금속 전극을 분리하는 실리콘 매트릭스에 삽입되었습니다. [1] 단락, 시추 진흙 손실, 완성 손상 및 유정 무결성 실패를 방지하기 위해 충전 시추 작업 중에 인근 유정을 차단해야 합니다. [2] nan [3]
Prevent Short Circuits 단락 방지
This provides a more reliable indication of raising concentrations of electroerosion products that prevents short circuits and breakage of wire electrodes. [1] The porous layer provides mechanical strength and is infiltrated with liquid and highly conductive NaAlCl4 salt, while the dense layer prevents short circuits. [2] The paper presents the results of a theoretical study of safety conditions for various groups of electrical equipment that affect single-phase networks in order to prevent short circuits on the case. [3]이것은 단락 및 와이어 전극 파손을 방지하는 전기 침식 제품의 농도를 높이는 더 신뢰할 수 있는 표시를 제공합니다. [1] 다공성 층은 기계적 강도를 제공하고 액체 및 전도성이 높은 NaAlCl4 염으로 침투되며 조밀한 층은 단락을 방지합니다. [2] nan [3]
Interturn Short Circuits 인터턴 단락
Interturn short circuits are a common fault of permanent magnet synchronous motors (PMSMs). [1] This paper deals with the topic of detecting and classifying one of the most common faults of permanent magnet synchronous motor – interturn short circuits. [2] In this paper we propose a strategy for detecting interturn short circuits on stator windings of three-phase induction motors (IM). [3]Interturn 단락은 영구 자석 동기 모터(PMSM)의 일반적인 결함입니다. [1] 이 논문은 영구자석 동기 전동기의 가장 일반적인 결함 중 하나인 인터턴 단락을 감지하고 분류하는 주제를 다룹니다. [2] nan [3]
Asymmetric Short Circuits 비대칭 단락
and use of an improved starting directional element makes it possible to increase its reliability in case of deep voltage drops and asymmetric short circuits. [1] In this case, the problems connected with the occurrence of fluxes exceeding the no-load fluxes under the conditions of symmetric and asymmetric short circuits, as well as the occurrence of buckling fluxes in these modes in the region outside the transformer iron, are solved. [2] The article deals with problems of research and analysis of voltages induced in protective shields of three phase shielded conductor in modes of asymmetric short circuits external to generators of power station. [3]개선된 시작 방향 요소를 사용하여 깊은 전압 강하 및 비대칭 단락의 경우 신뢰성을 높일 수 있습니다. [1] 이 경우 대칭 및 비대칭 단락 조건에서 무부하 자속을 초과하는 자속 발생과 관련된 문제와 변압기 철 외부 영역에서 이러한 모드의 좌굴 자속 발생과 관련된 문제가 해결됩니다. [2] nan [3]
Without Short Circuits
It is established that one of the ways by which it is possible to cut live multicore wires without short circuits is the use of abrasive cutting discs made of rotating electrocorundum. [1] Notably, the protective layer on Li-metal anode can be capable of inhibiting the growth of Li dendrite and the symmetrical Li-rGO-Li cell can maintain 500 cycles without short circuits. [2]단락 없이 라이브 멀티코어 와이어를 절단할 수 있는 방법 중 하나는 회전하는 전기강옥으로 만든 연마 절단 디스크를 사용하는 것입니다. [1] nan [2]
Cell Short Circuits 셀 단락
Anodic incidents occur when an aluminum electrolysis cell short circuits at an anode position. [1] Summary Lithium (Li)-metal is considered as promising anode material for high-energy-density rechargeable batteries, although its application is hampered by inhomogeneous Li deposition and dendritic Li morphologies that could eventually result in contact losses of bulk and deposited Li as well as cell short circuits. [2]양극 사고는 알루미늄 전해 전지가 양극 위치에서 단락될 때 발생합니다. [1] 요약 리튬(Li)-금속은 불균일한 Li 증착과 수지상 Li 형태로 인해 응용이 방해를 받고 있지만 궁극적으로 벌크 및 증착된 Li 및 셀 단락. [2]
External Short Circuits 외부 단락
The problems of determining the “weak” in terms of power transformers reliability of power systems based on the results of failure risk assessment due to external short circuits were solved by methods of fuzzy logic and probabilistic-statistical simulation of electric power system modes. [1] To consider the problems of modeling the processes of run-out, self-starting of a group of asynchronous electric motors (AM) in case of short-term power outages (NEC) and voltage drops in external short circuits (SC), convenient for programming and practical use. [2]외부 단락으로 인한 고장 위험 평가 결과를 기반으로 전력 계통의 전력 변압기 신뢰성 측면에서 "약함"을 결정하는 문제는 전력 계통 모드의 퍼지 논리 및 확률 통계적 시뮬레이션 방법으로 해결되었습니다. [1] 단기 정전(NEC) 및 외부 단락(SC)의 전압 강하 시 비동기 전기 모터(AM) 그룹의 런아웃, 자체 시작 프로세스 모델링 문제를 고려하여 편리한 프로그래밍 및 실제 사용. [2]
Ground Short Circuits 접지 단락
We present our approach for discrimination of pole-to-pole and pole-to-ground short circuits in VSC DC cables. [1] The application of the compression of the training sample of the Intelligent Discriminator of the modes of ground short circuits in the recognition of a single-phase short circuit to ground is demonstrated. [2]우리는 VSC DC 케이블에서 극 대 극 및 극 대 접지 단락을 구별하기 위한 접근 방식을 제시합니다. [1] 접지에 대한 단상 단락 인식에서 접지 단락 모드의 지능형 판별기의 훈련 샘플 압축 적용을 시연합니다. [2]
short circuits occur 단락 발생
As a consequence, short circuits occur, and the process breaks down. [1] This paper evaluates the electrical grid’s ability to sustain transient stability when three-phase solid short circuits occur, as well as the Critical Clearing Time whether wind turbines are present or not. [2] By considering different grounding methods of distribution bus side and DG side, distribution characteristics and change laws of fault current as well as sequence currents on both sides of fault point when single-phase short circuits occur in different positions of system are discussed. [3] As the insulation ages or is damaged, the wires between various transformer sections short circuits occur, which inevitably leads to a complete damage of the transformer. [4] Turn-to-turn short circuits occur due to insulation damage in transformer windings and these may potentially result in catastrophic faults affecting electric networks. [5]결과적으로 단락이 발생하고 프로세스가 중단됩니다. [1] 이 백서는 3상 솔리드 단락이 발생할 때 과도 안정성을 유지하는 전력망의 능력과 풍력 터빈이 있는지 여부에 관계없이 Critical Clearing Time을 평가합니다. [2] nan [3] nan [4] nan [5]
short circuits caused
By learning from experience, we can provide simple design changes that reduce the potential of things like short circuits caused by dropped wrenches. [1] The main challenge in the electricity networks VHV, HV or MV is to satisfy the customer and this by two important factors: the quality and continuity of service, that is why we must ensure the stability of the electricity network, this is the important role played by the protection systems participating to this goal, faced to a various faults affecting the electrical networks sometimes caused by thunderstorms, lightning, short circuits caused by other external objects, as well as earth faults … In most cases, electrical faults are manifested by mechanical damage, costing a lot of money. [2]경험을 통해 우리는 렌치 낙하로 인한 단락과 같은 가능성을 줄이는 간단한 설계 변경을 제공할 수 있습니다. [1] nan [2]
short circuits within 내부 단락
Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). [1] Single-line-to-ground (SLG) fault arcs cause the intermittent over-voltages, leading to short circuits within large-scale area. [2]변압기 권선 내의 턴 간 단락은 임펄스 전압 기반 주파수 응답 분석(IFRA)을 통해 진단할 수 있습니다. [1] SLG(Single-line-to-ground) 오류 아크는 간헐적인 과전압을 유발하여 대규모 영역 내에서 단락을 일으킵니다. [2]
short circuits fault 단락 오류
The paper presents a new practical and more precise model for induction motors after introducing inter turn short circuits faults. [1] The new technique is based on the fast Fourier transform of the currents in the output of the inverter with the aim of detecting short circuits faults in the Insulated Gate Bipolar Transistor (IGBT) switches of the inverter. [2]이 논문은 턴간 단락 오류를 도입한 후 유도 전동기에 대한 새롭고 실용적이고 정확한 모델을 제시합니다. [1] 새로운 기술은 인버터의 IGBT(Insulated Gate Bipolar Transistor) 스위치에서 단락 오류를 감지하기 위한 목적으로 인버터 출력 전류의 빠른 푸리에 변환을 기반으로 합니다. [2]