Rubidium Atomic(루비듐 원자)란 무엇입니까?
Rubidium Atomic 루비듐 원자 - The vapor-cell rubidium atomic clock is widely used in Global Navigation Satellite System (GNSS) and telecommunications. [1] Because of its relatively small cold atoms' collision frequency shift and ease of attaining high quantum state preparation efficiency, the rubidium atomic fountain clock has an indicated higher stability and reliability. [2] The system uses a cesium atomic clock as the reference clock source and transmits the signals through 8 small rubidium atomic clocks (RB clocks) hierarchically. [3] Both the short-term clock offset prediction accuracy and frequency stability were inferior to those of the rubidium atomic clock of the Global Positioning System (GPS) Block IIF satellites, the second-generation BeiDou Navigation Satellite System (BDS-2), Quasi-Zenith Satellite System (QZSS), and Galileo Passive Hydrogen Maser (PHM). [4] We discuss the applications of this algorithm by assessing the clock performance of all BDS3 satellites equipped with a passive hydrogen maser (PHM) or rubidium atomic clock. [5] We report a peak responsivity of ~30A/W for a wavelength of 780nm, which is ideal for on-chip integration with Rubidium atomic vapor. [6] When the frequency of the coupling field is fixed between [Formula: see text]–[Formula: see text] transition and the probe scans the [Formula: see text]–[Formula: see text] transitions, two-photon absorption (TPA) and electromagnetically induced transparent (EIT) peaks could be investigated simultaneously, and the amplitude of the peaks can be controlled by changing the temperature of rubidium atomic vapor cell and the probe field power. [7] Our high-precision microwave generation system consists of an optical frequency reference (iodine-stabilized laser) whose frequency is down-converted to the microwave region by using an optical frequency comb, and its frequency stability is expected to be three orders of magnitude higher than that of the current microwave generator (rubidium atomic clock) [1]. [8] A tunable near-infrared CW laser is phase locked to a commercial optical frequency comb referring to a Rubidium atomic clock for frequency stabilization. [9] We have the pulsed optically pumped (POP) rubidium atomic clock’s magnetic shielding system for the demagnetization experiment, the magnetic field value reached 1nT/7cm. [10] The results show that the frequency stability of the BDS-3 onboard passive hydrogen maser (PHM) and rubidium atomic frequency standard (RAFS) is competitive to those of the GPS IIF RAFS and Galileo FOC PHM and better than those of GPS IIR RAFS. [11] As one of the important circuits of the rubidium atomic clock, the C-field circuit plays a significant role in the rubidium atomic clock’s performance. [12] In this paper, we report the storage and retrieval of photonic qubits encoded with OAM state in an elongated cold rubidium atomic ensemble, achieving a storage efficiency around 65% with an average conditional fidelity above 98%. [13] Clock systematic characteristics, such as frequency accuracy and drift rate are examined and found that PHMs have better result than rubidium atomic clocks. [14] Here, we demonstrate tight, real-time phase synchronization of an optical frequency comb to a rubidium atomic clock. [15] Here, we present the study of many-body dipole-dipole interactions and correlations in potassium and rubidium atomic vapors by using double-quantum and multi-quantum 2DCS. [16] In this Letter, we study the collapse of a hybrid vector beam (HVB) propagating through rubidium atomic vapor. [17] Optical double-quantum two-dimensional coherent spectroscopy (2DCS) was implemented to probe interatomic dipole-dipole interactions in both potassium and rubidium atomic vapors. [18] Then, in accordance with this means, it develops a ten times frequency multiplier, finally achieving frequency multiplication taking the rubidium atomic frequency standard as a reference. [19] In this paper, we design a novel kind of microwave cavity in TE01U mode for rubidium atomic clock. [20] We report that the optical gain and intensity difference squeezing (IDS) of four-wave mixing can be controlled using an external dressing field in a hot rubidium atomic system. [21] The studied scenario consists of a steerable clock consisting of a micro phase stepper which changes the frequency of the output of an oven-controlled quartz oscillator (OCXO) and a rubidium atomic clock (RB). [22] For the applications that demand to address the issues of performance, portability, reliability, cost, weight, volume and power consumption, the Rubidium Atomic Frequency Standards (RAFS) are advantageous over other kinds of clocks [2, 3]. [23] A prototype of an UHV-compatible, crossed beam optical dipole trap at 1064 nm for application within a cold rubidium atomic quantum sensor currently in development at the Joint Lab Integrated Quantum Sensors at Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik is described. [24] A high-performance lamp-pumped rubidium atomic frequency standard (RAFS) prototype is developed. [25] As the primary frequency standard, BDS-3 satellites include two clock types with the passive hydrogen maser (PHM) and the rubidium atomic frequency standard (RAFS). [26] In this paper, theoretical and experimental research for a wide-range and self-locking rubidium atomic magnetometer based on free spin precession is presented. [27] In this paper, we propose an implementation of the compact laser system for POP rubidium atomic clock. [28] We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [29] We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [30] With the deployment of the Beidou-3, it is necessary to evaluate the performance of the new generation of on-board rubidium atomic clocks and hydrogen atomic clocks carried by Beidou-3 satellites. [31] A compact magnetron cavity having integrated optics is designed and realized for a rubidium atomic clock that is being developed for the Indian Regional Navigation Satellite System. [32] The calculated dependences of the orientational error of the rubidium atomic clock as a function of the time of movement of the Galileo and GPS satellites in orbit are given. [33] We report a tunable ring-shaped diffraction pattern via either nonlinear spatial self- or cross-phase modulation caused by the EIT-like effect in rubidium atomic vapor. [34] In contrast to cesium/rubidium atomic clocks, the THz OCS clock has fully electronic operations and, hence, a significantly simplified implementation. [35] In order to evaluate the performance of the atomic clock on timing terminal more reasonably, the frequency stability analysis of the rubidium atomic clock was carried out under the same experimental conditions, and the definitions of Allan variance and Hadamard variance were expounded. [36]증기 전지 루비듐 원자 시계는 GNSS(Global Navigation Satellite System) 및 통신에 널리 사용됩니다. [1] 상대적으로 차가운 원자의 충돌 주파수 이동이 작고 높은 양자 상태 준비 효율을 얻기 쉽기 때문에 루비듐 원자 만수시계는 더 높은 안정성과 신뢰성을 나타냅니다. [2] 시스템은 기준 클록 소스로 세슘 원자 시계를 사용하고 8개의 작은 루비듐 원자 시계(RB clock)를 통해 신호를 계층적으로 전송합니다. [3] 단기 시계 오프셋 예측 정확도와 주파수 안정성 모두 GPS(Global Positioning System) Block IIF 위성, 2세대 BeiDou Navigation Satellite System(BDS-2), Quasi-Zenith의 루비듐 원자 시계보다 열등했습니다. 위성 시스템(QZSS) 및 Galileo Passive Hydrogen Maser(PHM). [4] 수동 수소 메이저(PHM) 또는 루비듐 원자 시계가 장착된 모든 BDS3 위성의 시계 성능을 평가하여 이 알고리즘의 적용에 대해 논의합니다. [5] 우리는 루비듐 원자 증기와의 온칩 통합에 이상적인 780nm의 파장에 대해 ~30A/W의 피크 응답도를 보고합니다. [6] 커플링 필드의 주파수가 [Formula: 텍스트 참조]–[Formula: 텍스트 참조] 전환 사이에 고정되어 있고 프로브가 [Formula: 텍스트 참조]–[Formula: 텍스트 참조] 전환을 스캔할 때, 2광자 흡수(TPA ) 및 전자기 유도 투명(EIT) 피크를 동시에 조사할 수 있으며, 루비듐 원자 증기 전지의 온도와 프로브 필드 전력을 변경하여 피크의 진폭을 제어할 수 있습니다. [7] 당사의 고정밀 마이크로파 발생 시스템은 광주파수 빗을 이용하여 주파수를 마이크로파 영역으로 하향변환하는 광주파수 기준(요오드 안정화 레이저)으로 구성되며, 주파수 안정성은 현재 마이크로파 발생기(루비듐 원자 시계) [1]. [8] 조정 가능한 근적외선 CW 레이저는 주파수 안정화를 위한 루비듐 원자 시계를 참조하는 상용 광학 주파수 빗에 위상 고정됩니다. [9] 우리는 자기장 값이 1nT/7cm에 도달한 자화 실험을 위한 펄스 광학 펌핑(POP) 루비듐 원자 시계의 자기 차폐 시스템을 가지고 있습니다. [10] 결과는 BDS-3 온보드 수동 수소 메이저(PHM) 및 루비듐 원자 주파수 표준(RAFS)의 주파수 안정성이 GPS IIF RAFS 및 Galileo FOC PHM의 주파수 안정성과 경쟁적이며 GPS IIR RAFS의 주파수 안정성보다 우수함을 보여줍니다. [11] 루비듐 원자시계의 중요한 회로 중 하나인 C-field 회로는 루비듐 원자시계의 성능에 중요한 역할을 합니다. [12] 이 논문에서 우리는 긴 콜드 루비듐 원자 앙상블에서 OAM 상태로 인코딩된 광자 큐비트의 저장 및 검색을 보고하여 98% 이상의 평균 조건부 충실도와 함께 약 65%의 저장 효율성을 달성했습니다. [13] 주파수 정확도 및 드리프트 속도와 같은 클록 시스템 특성을 조사한 결과 PHM이 루비듐 원자 클록보다 더 나은 결과를 나타내는 것으로 나타났습니다. [14] nan [15] 여기에서는 이중 양자 및 다중 양자 2DCS를 사용하여 칼륨 및 루비듐 원자 증기의 다체 쌍극자-쌍극자 상호 작용 및 상관 관계에 대한 연구를 제시합니다. [16] 이 편지에서 우리는 루비듐 원자 증기를 통해 전파하는 하이브리드 벡터 빔(HVB)의 붕괴를 연구합니다. [17] 광학 이중 양자 2차원 간섭성 분광법(2DCS)은 칼륨 및 루비듐 원자 증기 모두에서 원자간 쌍극자-쌍극자 상호 작용을 조사하기 위해 구현되었습니다. [18] 그런 다음 이 방법에 따라 10배의 주파수 배율기를 개발하여 최종적으로 루비듐 원자 주파수 표준을 기준으로 주파수 배율을 달성합니다. [19] 이 논문에서 우리는 루비듐 원자 시계를 위한 TE01U 모드에서 새로운 종류의 마이크로파 공동을 설계합니다. [20] 우리는 뜨거운 루비듐 원자 시스템에서 외부 드레싱 필드를 사용하여 4파 혼합의 광학 이득 및 강도 차이 압착(IDS)을 제어할 수 있다고 보고합니다. [21] 연구된 시나리오는 오븐 제어 수정 발진기(OCXO)의 출력 주파수를 변경하는 마이크로 위상 스테퍼와 루비듐 원자 시계(RB)로 구성된 조정 가능한 시계로 구성됩니다. [22] 성능, 휴대성, 신뢰성, 비용, 무게, 부피 및 전력 소비 문제를 해결해야 하는 애플리케이션의 경우 RAFS(Rubidium Atomic Frequency Standards)가 다른 종류의 클록보다 유리합니다[2, 3]. [23] 독일 라이프니츠 연구소(Leibniz-Institut für Höchstfrequenztechnik)의 공동 연구실 통합 양자 센서(Joint Lab Integrated Quantum Sensors)에서 현재 개발 중인 저온 루비듐 원자 양자 센서 내에 적용하기 위한 1064nm에서 UHV 호환 교차 빔 광학 쌍극자 트랩의 프로토타입이 설명됩니다. [24] 고성능 램프 펌프 루비듐 원자 주파수 표준(RAFS) 프로토타입이 개발되었습니다. [25] 기본 주파수 표준인 BDS-3 위성에는 수동 수소 측정기(PHM)와 루비듐 원자 주파수 표준(RAFS)이 있는 두 가지 클록 유형이 포함됩니다. [26] 이 논문에서는 자유 스핀 세차를 기반으로 하는 넓은 범위의 자동 잠금 루비듐 원자 자력계에 대한 이론 및 실험 연구를 제시합니다. [27] 본 논문에서는 POP 루비듐 원자시계용 소형 레이저 시스템의 구현을 제안한다. [28] 우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [29] 우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [30] Beidou-3의 배치와 함께 Beidou-3 위성이 탑재한 차세대 루비듐 원자 시계와 수소 원자 시계의 성능을 평가할 필요가 있습니다. [31] 통합 광학이 있는 소형 마그네트론 공동은 인도 지역 항법 위성 시스템을 위해 개발 중인 루비듐 원자 시계를 위해 설계 및 구현되었습니다. [32] 궤도에 있는 갈릴레오 및 GPS 위성의 이동 시간의 함수로서 루비듐 원자 시계의 방향 오차의 계산된 의존성이 제공됩니다. [33] 우리는 루비듐 원자 증기에서 EIT와 같은 효과로 인한 비선형 공간 자체 또는 교차 위상 변조를 통해 조정 가능한 링 모양의 회절 패턴을 보고합니다. [34] 세슘/루비듐 원자 시계와 달리 THz OCS 시계는 완전히 전자적으로 작동하므로 구현이 크게 간소화됩니다. [35] 타이밍 단자에서 원자시계의 성능을 보다 합리적으로 평가하기 위하여 동일한 실험 조건에서 루비듐 원자시계의 주파수 안정성 분석을 수행하였고, Allan 분산과 Hadamard 분산의 정의를 설명하였다. [36]
passive hydrogen maser 패시브 수소 메이저
Both the short-term clock offset prediction accuracy and frequency stability were inferior to those of the rubidium atomic clock of the Global Positioning System (GPS) Block IIF satellites, the second-generation BeiDou Navigation Satellite System (BDS-2), Quasi-Zenith Satellite System (QZSS), and Galileo Passive Hydrogen Maser (PHM). [1] We discuss the applications of this algorithm by assessing the clock performance of all BDS3 satellites equipped with a passive hydrogen maser (PHM) or rubidium atomic clock. [2] The results show that the frequency stability of the BDS-3 onboard passive hydrogen maser (PHM) and rubidium atomic frequency standard (RAFS) is competitive to those of the GPS IIF RAFS and Galileo FOC PHM and better than those of GPS IIR RAFS. [3]단기 시계 오프셋 예측 정확도와 주파수 안정성 모두 GPS(Global Positioning System) Block IIF 위성, 2세대 BeiDou Navigation Satellite System(BDS-2), Quasi-Zenith의 루비듐 원자 시계보다 열등했습니다. 위성 시스템(QZSS) 및 Galileo Passive Hydrogen Maser(PHM). [1] 수동 수소 메이저(PHM) 또는 루비듐 원자 시계가 장착된 모든 BDS3 위성의 시계 성능을 평가하여 이 알고리즘의 적용에 대해 논의합니다. [2] 결과는 BDS-3 온보드 수동 수소 메이저(PHM) 및 루비듐 원자 주파수 표준(RAFS)의 주파수 안정성이 GPS IIF RAFS 및 Galileo FOC PHM의 주파수 안정성과 경쟁적이며 GPS IIR RAFS의 주파수 안정성보다 우수함을 보여줍니다. [3]
optical frequency comb 광 주파수 빗
Our high-precision microwave generation system consists of an optical frequency reference (iodine-stabilized laser) whose frequency is down-converted to the microwave region by using an optical frequency comb, and its frequency stability is expected to be three orders of magnitude higher than that of the current microwave generator (rubidium atomic clock) [1]. [1] A tunable near-infrared CW laser is phase locked to a commercial optical frequency comb referring to a Rubidium atomic clock for frequency stabilization. [2] Here, we demonstrate tight, real-time phase synchronization of an optical frequency comb to a rubidium atomic clock. [3]당사의 고정밀 마이크로파 발생 시스템은 광주파수 빗을 이용하여 주파수를 마이크로파 영역으로 하향변환하는 광주파수 기준(요오드 안정화 레이저)으로 구성되며, 주파수 안정성은 현재 마이크로파 발생기(루비듐 원자 시계) [1]. [1] 조정 가능한 근적외선 CW 레이저는 주파수 안정화를 위한 루비듐 원자 시계를 참조하는 상용 광학 주파수 빗에 위상 고정됩니다. [2] nan [3]
Cold Rubidium Atomic
In this paper, we report the storage and retrieval of photonic qubits encoded with OAM state in an elongated cold rubidium atomic ensemble, achieving a storage efficiency around 65% with an average conditional fidelity above 98%. [1] A prototype of an UHV-compatible, crossed beam optical dipole trap at 1064 nm for application within a cold rubidium atomic quantum sensor currently in development at the Joint Lab Integrated Quantum Sensors at Ferdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik is described. [2]이 논문에서 우리는 긴 콜드 루비듐 원자 앙상블에서 OAM 상태로 인코딩된 광자 큐비트의 저장 및 검색을 보고하여 98% 이상의 평균 조건부 충실도와 함께 약 65%의 저장 효율성을 달성했습니다. [1] 독일 라이프니츠 연구소(Leibniz-Institut für Höchstfrequenztechnik)의 공동 연구실 통합 양자 센서(Joint Lab Integrated Quantum Sensors)에서 현재 개발 중인 저온 루비듐 원자 양자 센서 내에 적용하기 위한 1064nm에서 UHV 호환 교차 빔 광학 쌍극자 트랩의 프로토타입이 설명됩니다. [2]
Optical Rubidium Atomic
We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [1] We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [2]우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [1] 우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [2]
rubidium atomic clock 루비듐 원자시계
The vapor-cell rubidium atomic clock is widely used in Global Navigation Satellite System (GNSS) and telecommunications. [1] The system uses a cesium atomic clock as the reference clock source and transmits the signals through 8 small rubidium atomic clocks (RB clocks) hierarchically. [2] Both the short-term clock offset prediction accuracy and frequency stability were inferior to those of the rubidium atomic clock of the Global Positioning System (GPS) Block IIF satellites, the second-generation BeiDou Navigation Satellite System (BDS-2), Quasi-Zenith Satellite System (QZSS), and Galileo Passive Hydrogen Maser (PHM). [3] We discuss the applications of this algorithm by assessing the clock performance of all BDS3 satellites equipped with a passive hydrogen maser (PHM) or rubidium atomic clock. [4] Our high-precision microwave generation system consists of an optical frequency reference (iodine-stabilized laser) whose frequency is down-converted to the microwave region by using an optical frequency comb, and its frequency stability is expected to be three orders of magnitude higher than that of the current microwave generator (rubidium atomic clock) [1]. [5] A tunable near-infrared CW laser is phase locked to a commercial optical frequency comb referring to a Rubidium atomic clock for frequency stabilization. [6] We have the pulsed optically pumped (POP) rubidium atomic clock’s magnetic shielding system for the demagnetization experiment, the magnetic field value reached 1nT/7cm. [7] As one of the important circuits of the rubidium atomic clock, the C-field circuit plays a significant role in the rubidium atomic clock’s performance. [8] Clock systematic characteristics, such as frequency accuracy and drift rate are examined and found that PHMs have better result than rubidium atomic clocks. [9] Here, we demonstrate tight, real-time phase synchronization of an optical frequency comb to a rubidium atomic clock. [10] In this paper, we design a novel kind of microwave cavity in TE01U mode for rubidium atomic clock. [11] The studied scenario consists of a steerable clock consisting of a micro phase stepper which changes the frequency of the output of an oven-controlled quartz oscillator (OCXO) and a rubidium atomic clock (RB). [12] In this paper, we propose an implementation of the compact laser system for POP rubidium atomic clock. [13] With the deployment of the Beidou-3, it is necessary to evaluate the performance of the new generation of on-board rubidium atomic clocks and hydrogen atomic clocks carried by Beidou-3 satellites. [14] A compact magnetron cavity having integrated optics is designed and realized for a rubidium atomic clock that is being developed for the Indian Regional Navigation Satellite System. [15] The calculated dependences of the orientational error of the rubidium atomic clock as a function of the time of movement of the Galileo and GPS satellites in orbit are given. [16] In contrast to cesium/rubidium atomic clocks, the THz OCS clock has fully electronic operations and, hence, a significantly simplified implementation. [17] In order to evaluate the performance of the atomic clock on timing terminal more reasonably, the frequency stability analysis of the rubidium atomic clock was carried out under the same experimental conditions, and the definitions of Allan variance and Hadamard variance were expounded. [18]증기 전지 루비듐 원자 시계는 GNSS(Global Navigation Satellite System) 및 통신에 널리 사용됩니다. [1] 시스템은 기준 클록 소스로 세슘 원자 시계를 사용하고 8개의 작은 루비듐 원자 시계(RB clock)를 통해 신호를 계층적으로 전송합니다. [2] 단기 시계 오프셋 예측 정확도와 주파수 안정성 모두 GPS(Global Positioning System) Block IIF 위성, 2세대 BeiDou Navigation Satellite System(BDS-2), Quasi-Zenith의 루비듐 원자 시계보다 열등했습니다. 위성 시스템(QZSS) 및 Galileo Passive Hydrogen Maser(PHM). [3] 수동 수소 메이저(PHM) 또는 루비듐 원자 시계가 장착된 모든 BDS3 위성의 시계 성능을 평가하여 이 알고리즘의 적용에 대해 논의합니다. [4] 당사의 고정밀 마이크로파 발생 시스템은 광주파수 빗을 이용하여 주파수를 마이크로파 영역으로 하향변환하는 광주파수 기준(요오드 안정화 레이저)으로 구성되며, 주파수 안정성은 현재 마이크로파 발생기(루비듐 원자 시계) [1]. [5] 조정 가능한 근적외선 CW 레이저는 주파수 안정화를 위한 루비듐 원자 시계를 참조하는 상용 광학 주파수 빗에 위상 고정됩니다. [6] 우리는 자기장 값이 1nT/7cm에 도달한 자화 실험을 위한 펄스 광학 펌핑(POP) 루비듐 원자 시계의 자기 차폐 시스템을 가지고 있습니다. [7] 루비듐 원자시계의 중요한 회로 중 하나인 C-field 회로는 루비듐 원자시계의 성능에 중요한 역할을 합니다. [8] 주파수 정확도 및 드리프트 속도와 같은 클록 시스템 특성을 조사한 결과 PHM이 루비듐 원자 클록보다 더 나은 결과를 나타내는 것으로 나타났습니다. [9] nan [10] 이 논문에서 우리는 루비듐 원자 시계를 위한 TE01U 모드에서 새로운 종류의 마이크로파 공동을 설계합니다. [11] 연구된 시나리오는 오븐 제어 수정 발진기(OCXO)의 출력 주파수를 변경하는 마이크로 위상 스테퍼와 루비듐 원자 시계(RB)로 구성된 조정 가능한 시계로 구성됩니다. [12] 본 논문에서는 POP 루비듐 원자시계용 소형 레이저 시스템의 구현을 제안한다. [13] Beidou-3의 배치와 함께 Beidou-3 위성이 탑재한 차세대 루비듐 원자 시계와 수소 원자 시계의 성능을 평가할 필요가 있습니다. [14] 통합 광학이 있는 소형 마그네트론 공동은 인도 지역 항법 위성 시스템을 위해 개발 중인 루비듐 원자 시계를 위해 설계 및 구현되었습니다. [15] 궤도에 있는 갈릴레오 및 GPS 위성의 이동 시간의 함수로서 루비듐 원자 시계의 방향 오차의 계산된 의존성이 제공됩니다. [16] 세슘/루비듐 원자 시계와 달리 THz OCS 시계는 완전히 전자적으로 작동하므로 구현이 크게 간소화됩니다. [17] 타이밍 단자에서 원자시계의 성능을 보다 합리적으로 평가하기 위하여 동일한 실험 조건에서 루비듐 원자시계의 주파수 안정성 분석을 수행하였고, Allan 분산과 Hadamard 분산의 정의를 설명하였다. [18]
rubidium atomic frequency
The results show that the frequency stability of the BDS-3 onboard passive hydrogen maser (PHM) and rubidium atomic frequency standard (RAFS) is competitive to those of the GPS IIF RAFS and Galileo FOC PHM and better than those of GPS IIR RAFS. [1] Then, in accordance with this means, it develops a ten times frequency multiplier, finally achieving frequency multiplication taking the rubidium atomic frequency standard as a reference. [2] For the applications that demand to address the issues of performance, portability, reliability, cost, weight, volume and power consumption, the Rubidium Atomic Frequency Standards (RAFS) are advantageous over other kinds of clocks [2, 3]. [3] A high-performance lamp-pumped rubidium atomic frequency standard (RAFS) prototype is developed. [4] As the primary frequency standard, BDS-3 satellites include two clock types with the passive hydrogen maser (PHM) and the rubidium atomic frequency standard (RAFS). [5] We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [6] We present a tabletop demonstration of free-space time-frequency transfer from a compact optical rubidium atomic frequency standard to stabilize a clock based on a fiber laser locked to fiber-delay line compared with a cavity-stabilized laser. [7]결과는 BDS-3 온보드 수동 수소 메이저(PHM) 및 루비듐 원자 주파수 표준(RAFS)의 주파수 안정성이 GPS IIF RAFS 및 Galileo FOC PHM의 주파수 안정성과 경쟁적이며 GPS IIR RAFS의 주파수 안정성보다 우수함을 보여줍니다. [1] 그런 다음 이 방법에 따라 10배의 주파수 배율기를 개발하여 최종적으로 루비듐 원자 주파수 표준을 기준으로 주파수 배율을 달성합니다. [2] 성능, 휴대성, 신뢰성, 비용, 무게, 부피 및 전력 소비 문제를 해결해야 하는 애플리케이션의 경우 RAFS(Rubidium Atomic Frequency Standards)가 다른 종류의 클록보다 유리합니다[2, 3]. [3] 고성능 램프 펌프 루비듐 원자 주파수 표준(RAFS) 프로토타입이 개발되었습니다. [4] 기본 주파수 표준인 BDS-3 위성에는 수동 수소 측정기(PHM)와 루비듐 원자 주파수 표준(RAFS)이 있는 두 가지 클록 유형이 포함됩니다. [5] 우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [6] 우리는 공동 안정화 레이저와 비교하여 광섬유 지연 라인에 고정된 광섬유 레이저를 기반으로 시계를 안정화하기 위해 소형 광학 루비듐 원자 주파수 표준에서 자유 공간 시간-주파수 전송의 탁상 시연을 제시합니다. [7]
rubidium atomic vapor 루비듐 원자 증기
We report a peak responsivity of ~30A/W for a wavelength of 780nm, which is ideal for on-chip integration with Rubidium atomic vapor. [1] When the frequency of the coupling field is fixed between [Formula: see text]–[Formula: see text] transition and the probe scans the [Formula: see text]–[Formula: see text] transitions, two-photon absorption (TPA) and electromagnetically induced transparent (EIT) peaks could be investigated simultaneously, and the amplitude of the peaks can be controlled by changing the temperature of rubidium atomic vapor cell and the probe field power. [2] Here, we present the study of many-body dipole-dipole interactions and correlations in potassium and rubidium atomic vapors by using double-quantum and multi-quantum 2DCS. [3] In this Letter, we study the collapse of a hybrid vector beam (HVB) propagating through rubidium atomic vapor. [4] Optical double-quantum two-dimensional coherent spectroscopy (2DCS) was implemented to probe interatomic dipole-dipole interactions in both potassium and rubidium atomic vapors. [5] We report a tunable ring-shaped diffraction pattern via either nonlinear spatial self- or cross-phase modulation caused by the EIT-like effect in rubidium atomic vapor. [6]우리는 루비듐 원자 증기와의 온칩 통합에 이상적인 780nm의 파장에 대해 ~30A/W의 피크 응답도를 보고합니다. [1] 커플링 필드의 주파수가 [Formula: 텍스트 참조]–[Formula: 텍스트 참조] 전환 사이에 고정되어 있고 프로브가 [Formula: 텍스트 참조]–[Formula: 텍스트 참조] 전환을 스캔할 때, 2광자 흡수(TPA ) 및 전자기 유도 투명(EIT) 피크를 동시에 조사할 수 있으며, 루비듐 원자 증기 전지의 온도와 프로브 필드 전력을 변경하여 피크의 진폭을 제어할 수 있습니다. [2] 여기에서는 이중 양자 및 다중 양자 2DCS를 사용하여 칼륨 및 루비듐 원자 증기의 다체 쌍극자-쌍극자 상호 작용 및 상관 관계에 대한 연구를 제시합니다. [3] 이 편지에서 우리는 루비듐 원자 증기를 통해 전파하는 하이브리드 벡터 빔(HVB)의 붕괴를 연구합니다. [4] 광학 이중 양자 2차원 간섭성 분광법(2DCS)은 칼륨 및 루비듐 원자 증기 모두에서 원자간 쌍극자-쌍극자 상호 작용을 조사하기 위해 구현되었습니다. [5] 우리는 루비듐 원자 증기에서 EIT와 같은 효과로 인한 비선형 공간 자체 또는 교차 위상 변조를 통해 조정 가능한 링 모양의 회절 패턴을 보고합니다. [6]