Polyethylene Implants(폴리에틸렌 임플란트)란 무엇입니까?
Polyethylene Implants 폴리에틸렌 임플란트 - After excluding patients with metal-on-polyethylene and with ceramic-on-polyethylene implants, 621 patients were considered eligible for this study. [1] METHODS We developed a Markov model to compare the cost-effectiveness of various implants against small-head cemented metal-on-polyethylene implants. [2] BACKGROUND Ceramic-on-polyethylene (CoP) implants have exhibited lower fretting and corrosion scores than metal-on-polyethylene implants. [3] Conclusion All-polyethylene implants are more sensitive to coronal plane malalignments than MB implants are; varus malalignment reduced cancellous bone strain but increased anteromedial cortical bone stress. [4] 4%), integrated hydroxyapatite or polyethylene implants (2; 4. [5]금속-폴리에틸렌 및 세라믹-폴리에틸렌 임플란트 환자를 제외한 후 621명의 환자가 이 연구에 적합한 것으로 간주되었습니다. [1] 행동 양식 우리는 다양한 임플란트의 비용 효율성을 small-head cemented metal-on-polyethylene 임플란트와 비교하기 위해 Markov 모델을 개발했습니다. [2] 배경 세라믹-폴리에틸렌(CoP) 임플란트는 금속-폴리에틸렌 임플란트보다 더 낮은 프레팅 및 부식 점수를 나타냅니다. [3] 결론 모든 폴리에틸렌 임플란트는 MB 임플란트보다 관상면 부정렬에 더 민감합니다. 내반 부정렬은 해면성 골 변형을 감소시켰지만 전내측 피질골 스트레스를 증가시켰습니다. [4] 4%), 통합 수산화인회석 또는 폴리에틸렌 임플란트(2, 4. [5]
Porou Polyethylene Implants 포루 폴리에틸렌 임플란트
Reconstruction is often performed using autologous costal cartilage (ACC) or porous polyethylene implants (PPE). [1] In addition, since the shrinking of mammalian bonederived hydroxyapatite orbital implants might result in a potential orbital volume loss, the use of nonmammalian bonederived, synthetic orbital implants, such as MEDPOR porous polyethylene implants, might reduce this risk. [2] Biomodel applications included surgical simulation, mirror imaging, pre-bending of internal fixation reconstruction plates, the provision of implant positioning/fabricating templates and cutting guides and the production of PoreStar® porous polyethylene implants fabricated for contour reconstruction. [3] Although porous polyethylene implants have previously been described as safe and effective for this purpose, surgeons should be aware of the risk of subsequent implant extrusion and chronic sphenoid sinusitis that can occur in a delayed manner. [4] The purpose of this study is to evaluate the intra- and post-operative performance and safety of direct three dimensional printing (3DP) porous polyethylene implants in cranial reconstruction. [5] The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. [6] Purpose: To describe the utilization of customized made-to-specification porous polyethylene implants and to evaluate clinical characteristics and outcomes of patients who received these implants for unilateral orbital defects. [7] Aim: The objective was to do a comparative study and to evaluate the outcome in overall acceptance for correction of residual facial deformity with autogenous graft versus porous polyethylene implants. [8]재건은 종종 자가 늑연골(ACC) 또는 다공성 폴리에틸렌 임플란트(PPE)를 사용하여 수행됩니다. [1] 또한, 포유동물 골유래 수산화인회석 안와 임플란트의 축소는 잠재적인 안와 부피 손실을 초래할 수 있으므로 MEDPOR 다공성 폴리에틸렌 임플란트와 같은 비포유동물 골유래 합성 안와 임플란트를 사용하면 이러한 위험을 줄일 수 있습니다. [2] 생체 모델 응용 프로그램에는 수술 시뮬레이션, 거울 이미징, 내부 고정 재건 플레이트의 사전 굽힘, 임플란트 위치 지정/제작 템플릿 및 절단 가이드 제공, 윤곽 재구성을 위해 제작된 PoreStar® 다공성 폴리에틸렌 임플란트 생산이 포함됩니다. [3] 다공성 폴리에틸렌 임플란트는 이전에 이 목적에 안전하고 효과적인 것으로 설명되었지만 외과의사는 지연된 방식으로 발생할 수 있는 후속 임플란트 돌출 및 만성 접형동염의 위험을 인식해야 합니다. [4] 이 연구의 목적은 두개골 재건에서 직접 3차원 인쇄(3DP) 다공성 폴리에틸렌 임플란트의 수술 중 및 수술 후 성능과 안전성을 평가하는 것입니다. [5] 문헌에는 다공성 폴리에틸렌 임플란트를 사용한 안와 바닥 재건술 후 8개월 및 3년 후에 발생하는 지연성 비외상성 안와 혈종에 대한 2건의 특정 보고서가 포함되어 있습니다. [6] 목적: 맞춤형 맞춤형 다공성 폴리에틸렌 보형물의 활용도를 설명하고 일측성 안와결손에 대해 이 보형물을 이식받은 환자의 임상적 특성과 결과를 평가하고자 하였다. [7] 목적: 자가 이식편과 다공성 폴리에틸렌 이식편의 잔존 안면 기형 교정에 대한 전반적인 수용도에 대한 비교 연구 및 결과를 평가하는 것이 목적이었다. [8]
Density Polyethylene Implants
It is hoped that these composite algMC-PCL scaffolds have potential for use in auricular (ear) cartilage regeneration as an alternative to current reconstructive treatments using autografted rib cartilage or high-density polyethylene implants. [1] BackgroundPorous high-density polyethylene implants (Medpor®) have been extensively used for septal extension grafts in Asian rhinoplasty. [2]이러한 복합 algMC-PCL 스캐폴드는 자가 이식된 늑골 연골 또는 고밀도 폴리에틸렌 임플란트를 사용하는 현재의 재건 치료에 대한 대안으로 귀 연골 재생에 사용할 가능성이 있기를 바랍니다. [1] 배경 다공성 고밀도 폴리에틸렌 임플란트(Medpor®)는 아시아 코 성형술에서 비중격 확장 이식편에 광범위하게 사용되었습니다. [2]