Polyethylene Cables(폴리에틸렌 케이블)란 무엇입니까?
Polyethylene Cables 폴리에틸렌 케이블 - Cross-linked polyethylene cables are used in distribution network cables on a large scale due to their excellent insulation properties, but dampness will seriously reduce the operating life of the cables. [1] Polypropylene (PP) environment-friendly thermoplastic cables without cross-linking have shown great potential, which tend to gradually substitute the traditional unrecyclable extruded cross-linked polyethylene cables. [2] The experimental validation of developed models is done by PD measurement on 11 kV cross-linked polyethylene cables. [3] In this study, conductance, dielectric and voltage withstanding performance of the insulating layers of cross-linked polyethylene cables with working voltage of 220 kV which was never used and has been used for 2, 4, 6 and 8 years were tested by various evaluation methods. [4] The most severe partial discharges and main insulation failures of 10 kV cross-linked polyethylene cables occur at the joint due to defects caused by various factors during the manufacturing and installation processes. [5]가교 폴리에틸렌 케이블은 우수한 절연 특성으로 인해 대규모 배전망 케이블에 사용되지만 습기는 케이블의 수명을 심각하게 단축시킵니다. [1] 가교가 없는 폴리프로필렌(PP) 친환경 열가소성 케이블은 큰 잠재력을 보여 기존의 재활용 불가능한 압출 가교 폴리에틸렌 케이블을 점차 대체하는 경향이 있습니다. [2] 개발된 모델의 실험적 검증은 11kV 가교 폴리에틸렌 케이블에 대한 PD 측정으로 수행됩니다. [3] 본 연구에서는 2, 4, 6, 8년간 사용된 적이 없고 사용된 전압이 220kV인 가교 폴리에틸렌 케이블의 절연층의 전도도, 유전율 및 내전압 성능을 다양한 평가 방법으로 테스트했습니다. . [4] 10kV 가교 폴리에틸렌 케이블의 가장 심각한 부분방전 및 주절연 불량은 제조 및 설치 과정에서 발생하는 다양한 요인에 의해 발생하는 결함으로 인해 접합부에서 발생합니다. [5]
Linked Polyethylene Cables
Cross-linked polyethylene cables are used in distribution network cables on a large scale due to their excellent insulation properties, but dampness will seriously reduce the operating life of the cables. [1] Polypropylene (PP) environment-friendly thermoplastic cables without cross-linking have shown great potential, which tend to gradually substitute the traditional unrecyclable extruded cross-linked polyethylene cables. [2] The experimental validation of developed models is done by PD measurement on 11 kV cross-linked polyethylene cables. [3] In this study, conductance, dielectric and voltage withstanding performance of the insulating layers of cross-linked polyethylene cables with working voltage of 220 kV which was never used and has been used for 2, 4, 6 and 8 years were tested by various evaluation methods. [4] The most severe partial discharges and main insulation failures of 10 kV cross-linked polyethylene cables occur at the joint due to defects caused by various factors during the manufacturing and installation processes. [5]가교 폴리에틸렌 케이블은 우수한 절연 특성으로 인해 대규모 배전망 케이블에 사용되지만 습기는 케이블의 수명을 심각하게 단축시킵니다. [1] 가교가 없는 폴리프로필렌(PP) 친환경 열가소성 케이블은 큰 잠재력을 보여 기존의 재활용 불가능한 압출 가교 폴리에틸렌 케이블을 점차 대체하는 경향이 있습니다. [2] 개발된 모델의 실험적 검증은 11kV 가교 폴리에틸렌 케이블에 대한 PD 측정으로 수행됩니다. [3] 본 연구에서는 2, 4, 6, 8년간 사용된 적이 없고 사용된 전압이 220kV인 가교 폴리에틸렌 케이블의 절연층의 전도도, 유전율 및 내전압 성능을 다양한 평가 방법으로 테스트했습니다. . [4] 10kV 가교 폴리에틸렌 케이블의 가장 심각한 부분방전 및 주절연 불량은 제조 및 설치 과정에서 발생하는 다양한 요인에 의해 발생하는 결함으로 인해 접합부에서 발생합니다. [5]