Polyethylene Acetabular(폴리에틸렌 비구)란 무엇입니까?
Polyethylene Acetabular 폴리에틸렌 비구 - METHODS A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. [1] METHODS Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) or a hydroxyapatite and titanium-coated monoblock shell with an integrated ceramic-on-ceramic bearing (n = 40). [2] AIMS We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty. [3] Conventional radiographs revealed peculiar signs of massive wear of the polyethylene acetabular liner (marked eccentricity of the prosthetic head and extensive osteolysis around the iliac screws), allowing to immediately conclude about the benign nature of the pathological fracture. [4] Conventional radiographs revealed peculiar signs of massive wear of the polyethylene acetabular liner (marked eccentricity of the prosthetic head and extensive osteolysis around the iliac screws), allowing to immediately conclude about the benign nature of the pathological fracture. [5] BACKGROUND The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). [6] INTRODUCTION Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. [7] All manufacturers with available studies have at least one report of 100% survivorship at 10-year follow-up for their titanium cup and highly crosslinked polyethylene acetabular component combination with aseptic loosening as an endpoint. [8]행동 양식 총 38명의 환자가 전향적으로 등록되었으며 비시멘트 모노블록 폴리에틸렌 비구(압입) 구성요소를 받았습니다. [1] 행동 양식 참가자들은 다공성 코팅된 모듈식 금속-폴리에틸렌 비구 구성요소(n=46) 또는 세라믹-세라믹 베어링이 통합된 수산화인회석 및 티타늄 코팅 모노블록 쉘(n=40)을 사용하여 고관절 교체를 받도록 무작위 배정되었습니다. . [2] 목표 우리는 가능한 가장 큰 코발트-크롬 헤드를 폴리에틸렌 비구 삽입물로 연결하는 것이 고관절 전치환술에서 생체 내 마모율을 증가시키는지 조사하는 것을 목표로 했습니다. [3] 기존의 방사선 사진은 폴리에틸렌 비구 라이너의 현저한 마모(보철 머리의 현저한 편심 및 장골 나사 주위의 광범위한 골용해)의 특이한 징후를 나타내어 병적 골절의 양성 특성에 대해 즉시 결론을 내릴 수 있습니다. [4] 기존의 방사선 사진은 폴리에틸렌 비구 라이너의 현저한 마모(보철 머리의 현저한 편심 및 장골 나사 주위의 광범위한 골용해)의 특이한 징후를 나타내어 병적 골절의 양성 특성에 대해 즉시 결론을 내릴 수 있습니다. [5] 배경 본 연구의 목적은 (1) 고도로 가교된 폴리에틸렌 비구 라이너의 최장 추적 마모 분석을 수행하고, (2) 대퇴골 및 비구 골용해의 발생률을 평가하고, (3) 비교하는 것입니다. 일차 고관절 전치환술(THA)에서 표준 및 융기된 림 비구 라이너 사이의 수술 결과. [6] 소개 고관절 교체 시 머리 삽입 관절 외에도 조립된 폴리에틸렌 비구 라이너의 뒷면과 금속 컵 사이의 미세 움직임으로 인해 추가 마모가 발생할 수 있습니다. [7] 사용 가능한 연구가 있는 모든 제조업체는 티타늄 컵과 무균 풀림을 종점으로 하는 고도로 가교된 폴리에틸렌 비구 구성 요소 조합에 대해 10년 추적 조사에서 100% 생존에 대한 보고서를 최소한 한 번 가지고 있습니다. [8]
polyethylene acetabular liner
Conventional radiographs revealed peculiar signs of massive wear of the polyethylene acetabular liner (marked eccentricity of the prosthetic head and extensive osteolysis around the iliac screws), allowing to immediately conclude about the benign nature of the pathological fracture. [1] Conventional radiographs revealed peculiar signs of massive wear of the polyethylene acetabular liner (marked eccentricity of the prosthetic head and extensive osteolysis around the iliac screws), allowing to immediately conclude about the benign nature of the pathological fracture. [2] BACKGROUND The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). [3] INTRODUCTION Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. [4]기존의 방사선 사진은 폴리에틸렌 비구 라이너의 현저한 마모(보철 머리의 현저한 편심 및 장골 나사 주위의 광범위한 골용해)의 특이한 징후를 나타내어 병적 골절의 양성 특성에 대해 즉시 결론을 내릴 수 있습니다. [1] 기존의 방사선 사진은 폴리에틸렌 비구 라이너의 현저한 마모(보철 머리의 현저한 편심 및 장골 나사 주위의 광범위한 골용해)의 특이한 징후를 나타내어 병적 골절의 양성 특성에 대해 즉시 결론을 내릴 수 있습니다. [2] 배경 본 연구의 목적은 (1) 고도로 가교된 폴리에틸렌 비구 라이너의 최장 추적 마모 분석을 수행하고, (2) 대퇴골 및 비구 골용해의 발생률을 평가하고, (3) 비교하는 것입니다. 일차 고관절 전치환술(THA)에서 표준 및 융기된 림 비구 라이너 사이의 수술 결과. [3] 소개 고관절 교체 시 머리 삽입 관절 외에도 조립된 폴리에틸렌 비구 라이너의 뒷면과 금속 컵 사이의 미세 움직임으로 인해 추가 마모가 발생할 수 있습니다. [4]
polyethylene acetabular component
METHODS Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) or a hydroxyapatite and titanium-coated monoblock shell with an integrated ceramic-on-ceramic bearing (n = 40). [1] All manufacturers with available studies have at least one report of 100% survivorship at 10-year follow-up for their titanium cup and highly crosslinked polyethylene acetabular component combination with aseptic loosening as an endpoint. [2]행동 양식 참가자들은 다공성 코팅된 모듈식 금속-폴리에틸렌 비구 구성요소(n=46) 또는 세라믹-세라믹 베어링이 통합된 수산화인회석 및 티타늄 코팅 모노블록 쉘(n=40)을 사용하여 고관절 교체를 받도록 무작위 배정되었습니다. . [1] 사용 가능한 연구가 있는 모든 제조업체는 티타늄 컵과 무균 풀림을 종점으로 하는 고도로 가교된 폴리에틸렌 비구 구성 요소 조합에 대해 10년 추적 조사에서 100% 생존에 대한 보고서를 최소한 한 번 가지고 있습니다. [2]